{"product_id":"wilo-nasslaufer-premium-smart-pumpen-stratos-maxo-30-0-5-10-pn10-g2-268w","title":"WILO Wet Rotor Premium Smart Pumps Stratos MAXO 30\/0.5-10 PN10, G2, 268W","description":"\u003cp\u003ePremium Smart Pump Wilo-Stratos MAXO\u003c\/p\u003e\u003cp\u003eHigh-efficiency inline glandless pump with EC motor and electronic power adjustment. Suitable for heating water, cold water, and water-glycol mixtures. Energy efficiency index (EEI) between ≤0.17 and ≤0.19 depending on the pump type.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eControl modes:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003ePermanent, automatic power adjustment to system requirements without setpoint input \u003cb\u003eWilo-Dynamic Adapt plus\u003c\/b\u003e (factory setting). Up to 20% energy savings compared to dp-v control mode.\u003c\/li\u003e\n\n\u003cli\u003eConstant temperature \u003cb\u003e(T-const.)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eConstant differential temperature \u003cb\u003e(dT-const.)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eDemand-optimized flow rate optimization of the feeder pump through networking and communication with multiple pumps \u003cb\u003e(Multi-Flow Adaptation).\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eConstant flow rate \u003cb\u003e(Q-const.)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eDifferential pressure control dp-c at a remote point in the pipe network \u003cb\u003e(worst-point control)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eConstant differential pressure \u003cb\u003e(dp-c)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eVariable differential pressure \u003cb\u003e(dp-v) \u003c\/b\u003ewith the option of nominal operating point input\u003c\/li\u003e\n\n\u003cli\u003eConstant speed \u003cb\u003e(n-const.)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eUser-defined \u003cb\u003ePID\u003c\/b\u003e control\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFunctions:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eHeat quantity detection\u003c\/li\u003e\n\n\u003cli\u003eCold quantity detection\u003c\/li\u003e\n\n\u003cli\u003eAutomatic pump shutdown on zero flow detection \u003cb\u003e(No-Flow Stop)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eSwitching between heating and cooling operation (automatic, external or manual)\u003c\/li\u003e\n\n\u003cli\u003eAdjustable flow rate limitation via Q-Limit function \u003cb\u003e(Q\u003c\/b\u003e\u003cb\u003emin.\u003c\/b\u003e\u003cb\u003e and Q\u003c\/b\u003e\u003cb\u003emax.\u003c\/b\u003e\u003cb\u003e)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eDual pump operating modes: Efficiency-optimized \u003cb\u003eaddition mode\u003c\/b\u003e for dp-c and dp-v, main\/standby mode\u003c\/li\u003e\n\n\u003cli\u003eSaving and restoring configured pump settings \u003cb\u003e(3 restore points)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eFault message\/warning message display\u003c\/b\u003e in plain text including troubleshooting recommendations\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eVenting function\u003c\/b\u003e for automatic venting of the rotor chamber\u003c\/li\u003e\n\n\u003cli\u003eAutomatic \u003cb\u003enight setback\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eAutomatic \u003cb\u003edeblocking function\u003c\/b\u003e and integrated \u003cb\u003efull motor protection\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\u003cb\u003eDry-running detection\u003c\/b\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDisplay:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eControl mode\u003c\/li\u003e\n\n\u003cli\u003eSetpoint\u003c\/li\u003e\n\n\u003cli\u003eFlow rate\u003c\/li\u003e\n\n\u003cli\u003eTemperature\u003c\/li\u003e\n\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\n\u003cli\u003eElectrical consumption\u003c\/li\u003e\n\n\u003cli\u003eActive influences (e.g. STOP, No-Flow Stop)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDesign:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cb\u003e2\u003c\/b\u003e configurable \u003cb\u003eanalog inputs\u003c\/b\u003e: 0-10V, 2-10V, 0-20mA, 4-20mA and commercially available Pt1000, power supply with +24VDC\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003e2\u003c\/b\u003e configurable \u003cb\u003edigital inputs\u003c\/b\u003e (Ext. OFF, Ext. Min, Ext. Max, Heating\/Cooling, Manual Override (Building Automation decoupled), Operating Lock (Keypad Lock and Remote Control Configuration Protection))\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003e2\u003c\/b\u003e configurable \u003cb\u003esignal relays\u003c\/b\u003e for \u003cb\u003eoperating and fault messages\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eSlot for Wilo-CIF modules\u003c\/b\u003e with interfaces for building automation GA (Optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS\/TP, BACnet IP, LON, PLR, CANopen)\u003c\/li\u003e\n\n\u003cli\u003eWilo Net as Wilo system bus for communication between Wilo products, e.g. \u003cb\u003eMulti-Flow Adaptation\u003c\/b\u003e, dual pump operation and Wilo-Smart Gateway\u003c\/li\u003e\n\n\u003cli\u003e\u003cb\u003eIntegrated temperature sensor\u003c\/b\u003e\u003c\/li\u003e\n\n\u003cli\u003eAutomatic \u003cb\u003eemergency operation\u003c\/b\u003e in special situations (pump speed definable) e.g. in case of bus communication failure or sensor value failures\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eGraphical color display\u003c\/b\u003e (4.3 inch) with one-button manual control\u003c\/li\u003e\n\n\u003cli\u003eReading and setting operating data as well as e.g. creating a commissioning report via Bluetooth interface (without additional accessories) using the Wilo Assistant App\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eIntegrated dual pump management\u003c\/b\u003e (dual pumps are pre-wired), when using 2 single pumps as a dual pump unit, connection via WILO Net\u003c\/li\u003e\n\n\u003cli\u003eCable break detection for analog signal (in conjunction with 2-10V or 4-20mA)\u003c\/li\u003e\n\n\u003cli\u003eOutdoor installation with weather protection possible according to installation and operating instructions\u003c\/li\u003e\n\n\u003cli\u003eDate and time pre-set\u003c\/li\u003e\n\n\u003cli\u003eThermal insulation shell for heating applications\u003c\/li\u003e\n\n\u003cli\u003e5-year warranty\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eScope of delivery\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003ePump\u003c\/li\u003e\n\n\u003cli\u003eOptimized Wilo-Connector identical for all sizes\u003c\/li\u003e\n\n\u003cli\u003e2x cable gland M16 x 1.5\u003c\/li\u003e\n\n\u003cli\u003eWashers for flange screws M12 and M16 (for nominal connection sizes DN32 to DN65)\u003c\/li\u003e\n\n\u003cli\u003e2x gaskets for threaded connection\u003c\/li\u003e\n\n\u003cli\u003eThermal insulation shell\u003c\/li\u003e\n\n\u003cli\u003eInstallation and operating instructions (digital)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eOptional accessories:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eClimaForm cold insulation to prevent condensation\u003c\/li\u003e\n\n\u003cli\u003eCIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS\/TP, LON, PLR, CANopen\u003c\/li\u003e\n\n\u003cli\u003ePt1000 (B) pipe clamp sensor (for domestic hot water)\u003c\/li\u003e\n\n\u003cli\u003ePt1000 (AA) sensor for installation in immersion sleeve\u003c\/li\u003e\n\n\u003cli\u003eDifferential pressure sensor\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eOperating data\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eFluid media: Water, ethylene glycol, propylene glycol\u003c\/li\u003e\n\n\u003cli\u003eMin. media temperature: -10 °C\u003c\/li\u003e\n\n\u003cli\u003eMax. media temperature: 110 °C\u003c\/li\u003e\n\n\u003cli\u003eMin. ambient temperature: -10 °C\u003c\/li\u003e\n\n\u003cli\u003eMax. ambient temperature: 40 °C\u003c\/li\u003e\n\n\u003cli\u003eMaximum operating pressure: 10 bar\u003c\/li\u003e\n\n\u003cli\u003eMinimum inlet head at 50°C: 3 m\u003c\/li\u003e\n\n\u003cli\u003eMinimum inlet head at 95°C: 10 m\u003c\/li\u003e\n\n\u003cli\u003eMinimum inlet head at 110°C: 16 m\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eMotor data\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eEnergy efficiency index (EEI): 0.19\u003c\/li\u003e\n\n\u003cli\u003eMains connection: 1~230 V ±10%, 50\/60 Hz\u003c\/li\u003e\n\n\u003cli\u003eCurrent (min): 0.11 A\u003c\/li\u003e\n\n\u003cli\u003eCurrent (max): 1.2 A\u003c\/li\u003e\n\n\u003cli\u003eMotor nominal power: 234 W\u003c\/li\u003e\n\n\u003cli\u003eSpeed min.: 750 rpm\u003c\/li\u003e\n\n\u003cli\u003eSpeed max.: 3950 rpm\u003c\/li\u003e\n\n\u003cli\u003ePower consumption: 7 W\u003c\/li\u003e\n\n\u003cli\u003ePower consumption: 275 W\u003c\/li\u003e\n\n\u003cli\u003eInterference emission: EN 61800-3,2004+A1,2012 \/ Residential area (C1)\u003c\/li\u003e\n\n\u003cli\u003eInterference immunity: EN 61800-3,2004+A1,2012 \/ Industrial area (C2)\u003c\/li\u003e\n\n\u003cli\u003eInsulation class: F\u003c\/li\u003e\n\n\u003cli\u003eProtection class: IPX4D\u003c\/li\u003e\n\n\u003cli\u003eCable gland: 5 x M16x1.5\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eMaterials\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003ePump casing: Cast iron\u003c\/li\u003e\n\n\u003cli\u003eImpeller: PPS-GF40\u003c\/li\u003e\n\n\u003cli\u003eShaft: 1.4122, DLC-coated\u003c\/li\u003e\n\n\u003cli\u003eBearing: Carbon, antimony-impregnated\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eInstallation dimensions\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003ePump connection: G 2\u003c\/li\u003e\n\n\u003cli\u003ePump connection (alternative designation): RP 1 1\/2DN 30\u003c\/li\u003e\n\n\u003cli\u003eOverall length: 180 mm\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eOrder information\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eManufacturer: Wilo\u003c\/li\u003e\n\n\u003cli\u003eProduct designation: Stratos MAXO 30\/0.5-10 PN 10\u003c\/li\u003e\n\n\u003cli\u003eNet weight approx.: 7.5 kg\u003c\/li\u003e\n\n\u003cli\u003eArticle number: 2186191\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"Wilo","offers":[{"title":"1","offer_id":56543852986754,"sku":"WCW-0209928-001","price":1159.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0928\/3675\/7890\/files\/8_4_c_5_84c5ea8c4bf705d250d0a9d00dec43a79915bafe_wcw_0209928_gl_image1_converted_500x500_wib_wilo1480442_jpg.jpg?v=1783548097","url":"https:\/\/bauraum24.de\/en\/products\/wilo-nasslaufer-premium-smart-pumpen-stratos-maxo-30-0-5-10-pn10-g2-268w","provider":"Bauraum24","version":"1.0","type":"link"}