{"product_id":"wilo-nasslaufer-premium-smart-pumpen-stratos-maxo-25-0-5-12-pn10-g11-2-283w","title":"WILO Wet Rotor Premium Smart Pumps Stratos MAXO 25\/0.5-12 PN10,G11\/2,283W","description":"\u003cp\u003ePremium Smart-Pump Wilo-Stratos MAXO\u003c\/p\u003e\u003cp\u003eHigh-efficiency inline glandless circulator with EC motor and electronic power adjustment. Can be used for heating water, cold water, and water-glycol mixtures. Energy Efficiency Index (EEI) depending on the pump type between ≤0.17 and ≤0.19.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eControl modes:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003ePermanent, automatic power adjustment to system requirements without setpoint input \u003cb\u003eWilo-Dynamic Adapt plus\u003c\/b\u003e (factory setting). Up to 20% energy saving compared to dp-v control mode.\u003c\/li\u003e\n\n\u003cli\u003eConstant temperature \u003cb\u003e(T-const.)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eConstant differential temperature \u003cb\u003e(dT-const.)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eDemand-driven flow optimisation of the booster pump through networking and communication with multiple pumps \u003cb\u003e(Multi-Flow Adaptation).\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eConstant flow rate \u003cb\u003e(Q-const.)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eDifferential pressure control dp-c at a remote point in the pipe network \u003cb\u003e(critical point control)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eConstant differential pressure \u003cb\u003e(dp-c)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eVariable differential pressure \u003cb\u003e(dp-v)\u003c\/b\u003e with the option of nominal operating point input\u003c\/li\u003e\n\n\u003cli\u003eConstant speed \u003cb\u003e(n-const.)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eUser-defined \u003cb\u003ePID\u003c\/b\u003e control\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFunctions:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eHeat quantity detection\u003c\/li\u003e\n\n\u003cli\u003eCooling quantity detection\u003c\/li\u003e\n\n\u003cli\u003eAutomatic pump shutdown on zero flow detection \u003cb\u003e(No-Flow Stop)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eSwitching between heating and cooling operation (automatic, external or manual)\u003c\/li\u003e\n\n\u003cli\u003eAdjustable flow limitation by Q-Limit function \u003cb\u003e(Q\u003c\/b\u003e\u003cb\u003emin.\u003c\/b\u003e\u003cb\u003e and Q\u003c\/b\u003e\u003cb\u003emax.\u003c\/b\u003e\u003cb\u003e)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eDual pump operating modes: Efficiency-optimised \u003cb\u003eaddition operation\u003c\/b\u003e for dp-c and dp-v, main\/standby operation\u003c\/li\u003e\n\n\u003cli\u003eSaving and restoring configured pump settings \u003cb\u003e(3 restore points)\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eFault\/warning message display\u003c\/b\u003e in plain text including recommended remedies\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eVentilation function\u003c\/b\u003e for automatic venting of the rotor chamber\u003c\/li\u003e\n\n\u003cli\u003eAutomatic \u003cb\u003enight setback\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eAutomatic \u003cb\u003edeblocking function\u003c\/b\u003e and integrated \u003cb\u003efull motor protection\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cb\u003eDry-running detection\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDisplay:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eControl mode\u003c\/li\u003e\n\n\u003cli\u003eSetpoint\u003c\/li\u003e\n\n\u003cli\u003eFlow rate\u003c\/li\u003e\n\n\u003cli\u003eTemperature\u003c\/li\u003e\n\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\n\u003cli\u003eElectrical consumption\u003c\/li\u003e\n\n\u003cli\u003eActive influences (e.g. STOP, No-Flow Stop)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eDesign:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cb\u003e2\u003c\/b\u003e configurable \u003cb\u003eanalogue inputs\u003c\/b\u003e: 0-10V, 2-10V, 0-20mA, 4-20mA and commercial Pt1000, power supply with +24VDC\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003e2\u003c\/b\u003e configurable \u003cb\u003edigital inputs\u003c\/b\u003e (Ext. OFF, Ext. Min, Ext. Max, Heating\/Cooling, Manual override (Building Automation disconnected), Operation lock (button lock and remote control configuration protection))\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003e2\u003c\/b\u003e configurable \u003cb\u003esignal relays\u003c\/b\u003e for \u003cb\u003eoperating and fault messages\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eSlot for Wilo-CIF modules\u003c\/b\u003e with interfaces for building automation BA (Optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS\/TP, BACnet IP, LON, PLR, CANopen)\u003c\/li\u003e\n\n\u003cli\u003eWilo Net as Wilo system bus for communication between Wilo products, e.g. \u003cb\u003eMulti-Flow Adaptation\u003c\/b\u003e, dual pump operation and Wilo-Smart Gateway\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cb\u003eIntegrated temperature sensor\u003c\/b\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eAutomatic \u003cb\u003eemergency operation\u003c\/b\u003e in special conditions (pump speed definable) e.g. in case of bus communication failure or sensor value failure\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eGraphical colour display\u003c\/b\u003e (4.3 inch) with operation via one-button manual control level\u003c\/li\u003e\n\n\u003cli\u003eReading and setting operating data as well as creating a commissioning report via Bluetooth interface (without additional accessories) using the Wilo Assistant App\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cb\u003eDual pump management\u003c\/b\u003e integrated (dual pumps are pre-wired), when using 2 single pumps as a dual pump unit, connection via WILO Net\u003c\/li\u003e\n\n\u003cli\u003eCable break detection for analogue signal (in conjunction with 2-10V or 4-20mA)\u003c\/li\u003e\n\n\u003cli\u003eOutdoor installation with weather protection possible according to installation and operating instructions\u003c\/li\u003e\n\n\u003cli\u003eDate and time pre-set\u003c\/li\u003e\n\n\u003cli\u003eThermal insulation shell for heating applications\u003c\/li\u003e\n\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eScope of delivery\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003ePump\u003c\/li\u003e\n\n\u003cli\u003eOptimised Wilo-Connector for all sizes\u003c\/li\u003e\n\n\u003cli\u003e2x cable gland M16 x 1.5\u003c\/li\u003e\n\n\u003cli\u003eWashers for flange screws M12 and M16 (for nominal connection sizes DN32 to DN65)\u003c\/li\u003e\n\n\u003cli\u003e2x gaskets for threaded connection\u003c\/li\u003e\n\n\u003cli\u003eThermal insulation shell\u003c\/li\u003e\n\n\u003cli\u003eInstallation and operating instructions (digital)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eOptional accessories:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eClimaForm cold insulation to prevent condensation\u003c\/li\u003e\n\n\u003cli\u003eCIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS\/TP, LON, PLR, CANopen\u003c\/li\u003e\n\n\u003cli\u003ePt1000 (B) pipe clamp sensor (for domestic hot water)\u003c\/li\u003e\n\n\u003cli\u003ePt1000 (AA) sensor for installation in immersion sleeve\u003c\/li\u003e\n\n\u003cli\u003eDifferential pressure sensor\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eOperating data\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003ePumping medium: Water, ethylene glycol, propylene glycol\u003c\/li\u003e\n\n\u003cli\u003eMin. medium temperature: -10 °C\u003c\/li\u003e\n\n\u003cli\u003eMax. medium temperature: 110 °C\u003c\/li\u003e\n\n\u003cli\u003eMin. ambient temperature: -10 °C\u003c\/li\u003e\n\n\u003cli\u003eMax. ambient temperature: 40 °C\u003c\/li\u003e\n\n\u003cli\u003eMaximum operating pressure: 10 bar\u003c\/li\u003e\n\n\u003cli\u003eMinimum inlet head at 50°C: 3 m\u003c\/li\u003e\n\n\u003cli\u003eMinimum inlet head at 95°C: 10 m\u003c\/li\u003e\n\n\u003cli\u003eMinimum inlet head at 110°C: 16 m\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eMotor data\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eEnergy Efficiency Index (EEI): 0.19\u003c\/li\u003e\n\n\u003cli\u003eMains connection: 1~230 V ±10%, 50\/60 Hz\u003c\/li\u003e\n\n\u003cli\u003eCurrent (min): 0.11 A\u003c\/li\u003e\n\n\u003cli\u003eCurrent (max): 1.28 A\u003c\/li\u003e\n\n\u003cli\u003eNominal motor power: 262 W\u003c\/li\u003e\n\n\u003cli\u003eSpeed min.: 750 rpm\u003c\/li\u003e\n\n\u003cli\u003eSpeed max.: 4350 rpm\u003c\/li\u003e\n\n\u003cli\u003ePower consumption: 7 W\u003c\/li\u003e\n\n\u003cli\u003ePower consumption: 295 W\u003c\/li\u003e\n\n\u003cli\u003eEmissions: EN 61800-3,2004+A1,2012 \/ Residential (C1)\u003c\/li\u003e\n\n\u003cli\u003eImmunity: EN 61800-3,2004+A1,2012 \/ Industrial (C2)\u003c\/li\u003e\n\n\u003cli\u003eInsulation class: F\u003c\/li\u003e\n\n\u003cli\u003eProtection class: IPX4D\u003c\/li\u003e\n\n\u003cli\u003eCable gland: 5 x M16x1.5\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eMaterials\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003ePump housing: Cast iron\u003c\/li\u003e\n\n\u003cli\u003eImpeller: PPS-GF40\u003c\/li\u003e\n\n\u003cli\u003eShaft: 1.4122, DLC-coated\u003c\/li\u003e\n\n\u003cli\u003eBearing: Carbon, antimony-impregnated\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eInstallation dimensions\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003ePump connection: G 1½\u003c\/li\u003e\n\n\u003cli\u003ePump connection (alternative designation): RP 1DN 25\u003c\/li\u003e\n\n\u003cli\u003eOverall length: 180 mm\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003eOrdering information\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003eManufacturer: Wilo\u003c\/li\u003e\n\n\u003cli\u003eProduct designation: Stratos MAXO 25\/0.5-12 PN 10\u003c\/li\u003e\n\n\u003cli\u003eNet weight approx.: 7.5 kg\u003c\/li\u003e\n\n\u003cli\u003eArticle number: 2186187\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"Wilo","offers":[{"title":"1","offer_id":56543852265858,"sku":"WCW-0209924-001","price":1322.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0928\/3675\/7890\/files\/d_e_f_8_def8cc86bd06d3740b9c0134d96278ab6aabae31_wcw_0209924_gl_image1_converted_500x500_wib_wilo1480442_jpg.jpg?v=1783548074","url":"https:\/\/bauraum24.de\/en\/products\/wilo-nasslaufer-premium-smart-pumpen-stratos-maxo-25-0-5-12-pn10-g11-2-283w","provider":"Bauraum24","version":"1.0","type":"link"}